Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenRail Designer

Showing 1151

Annotation Group Definition Copied to Active File when Used

When labeling civil geometry (alignments for example), whichever annotation group that is utilized is copied from the DNGLIB and saved with the active DGN. This is only the case when the geometry being annotated is stored within the active DGN, no...
3 months ago in Drawing Production / OpenRail Designer / OpenRoads Designer / Workspace 0 Future consideration

Issues with Drainage Prompt to compress database

The prompt for compressing the drainage database needs some work: It really should be removed. Salvaging anything marked for deletion but not compressed isn't really feasible in OpenRoads environment. Do not prompt me twice. It should be assumed t...
3 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 1 Future consideration

ORD SUDA - Single gradient property - False for stormwater and wastewater conduit

Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit. "Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
3 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 2 Future consideration

Add BETWEEN values to display rules

When using display rules Type it would be useful to have an option of values between A-B, not only >, = , and >=. This way you can choose between multiple versions of a component. Example absolute horizontal 0-1 Curb type F, 1-2 type A, 2-3 ...
about 1 year ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Ability to modify 'Rational Method Frequency Adjustment Factor' for a specific catchment or range of catchments.

Currently there is only an option to add Rational Method Frequency Adjustment Factors for the entire storm, which affects all catchments. Our GDOT standards require modification of the factor for only C values less than 0.6.
over 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Gauge and Cant Reports on Regression Information

Based on the way the new regression tools work for importing regression lines we no longer have a way of running gauge and cant reports on existing alignments based on LHR/RHR surveys.
over 1 year ago in CANT / OpenRail Designer / Regression Analysis / Reports 0 Future consideration

Add Conduit To Existing Profile Run

It would be very helpful if there was a way to simply Add a Conduit to an existing Profile Run. For example, I have a storm network modeled and a bunch of drawings created by using a Profile Run, but now I needed to add another conduit at the end ...
3 months ago in Drainage and Utilities / Drawing Production / OpenRail Designer / OpenRoads Designer 0 Future consideration

Georeferenced Sheet Models

Sheet models do not inherit the coordinate system from the Design model when created. The goal is to be able to create a georeferenced pdf that lays flat on aerial photography.

Add temporary/permanent button on civil analysis tool for placing graphic elements, or at least make them a graphic group to make removing them easier and more complete.

When I use the civil analysis tool, I sometimes place the displayed graphics (elevation, contour, triangle) into the drawing to have a record. The problem is when I am done with the graphic and want to remove them, I have to select each component ...
10 months ago in Analytics / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Ability to edit Annotation Groups in any model

It's a little cumbersome to keep going back and forth between models when developing annotation groups. An alternative could be to be able to select the geometry that is shown as the example when in the annotation group manager.
over 2 years ago in Annotation / OpenRail Designer / OpenRoads Designer / OpenSite Designer / Workspace 0 Future consideration