Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Applications

Showing 1524

Make the Drainage Catch Basin Grate Perimeter and Open Area variables reportable

Some DOTs require input of an exact values for catch basin grate open area for orifice flow and catch basin grate perimeter for weir flow. ORD would consider these as calculated values, not inputs. These are not ORD outputs and are hidden from the...
3 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 0 Future consideration

Allow Esri Shapefile Field Name to be longer than 10 characters

When exporting a drainage flex table in ESRI format, the default field names include names longer than 10 characters. This throws the error message: "The Esri Shapefile field name <Middle_Flow> for column <Flow (Middle)> cannot be long...
3 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 0 Future consideration

Variable that stores Format Options and makes them predefined in a workspace.

Currently as an OpenRoads Designer user, when the user changes the Format Options, the changes are stored on the user’s computer. This results in many different options being used in delivered reports. I would like to have an environment variable ...
over 2 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Workspace 1 Future consideration

Option to refresh/update/revise geometry point sequencing

When designing different types of sites/pads etc, it is very typical to provide set out points on our drawings. The issue is that designs can change requiring us to remove certain points which will leave a gap in the point sequencing. There needs ...
about 2 months ago in Geometry / OpenRoads Designer 0 Future consideration

Productivity enhancements to Corridor Objects dialog

There are currently some things needed to be added to the Corridor Object dialog to help communicate design intent a bit better to users (especially with Parametric Constraints): The lack of information as to the rules linked to Parametric Constra...
about 3 years ago in Modeling / OpenRail Designer / OpenRoads Designer 1 Future consideration

Need ability to include General Project information in the IFC

This is the Feature Request to support the ability to include General Project information in the IFC. We would like to add several user-defined attributes to the IFC Site level, including "Organization Name", "Project Address", "Project Issue Date...
over 1 year ago in Import/Export / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Use Cells for creation of sleepers

Support use of cell definitions for sleeper placements. Long sleeper sets placed at turnout locations, have variable width so these will still be using existing box shaped sleepers but normal sleepers will be using the cell based definitions. This...
about 3 years ago in Modeling / OpenRail Designer 0 Future consideration

Make editing catchment areas more user friendly

When you initially create a drainage area from a shape, it creates 'smart' vertices that you can grab and move with the cursor. However, after the initial catchment shape is created, the only way to add additional vertices is using the "Insert Ver...

Command to locate the midpoint between 2 points ala MTP or M2P in C3D

A command where, once activated, would prompt the user to select the first point, then the second point, and then the user's cursor would snap to a location located exactly in between the two points. This could be done without drawing any unnecess...
about 2 months ago in OpenRoads Designer 0 Future consideration

Split Drainage Node Baseline Reference into Station Reference and Offset Reference

Drainage nodes currently utilize an Elevation Reference and a Baseline Reference. It would be better to split the Baseline Reference into two separate references, 1) "Station Reference", and 2) "Offset Reference". In practice, this would allow a n...
about 2 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / User Interface 0 Already exists