Bentley Civil Product Ideas

Showing 1753 of 1753

Annotation Group Definition Copied to Active File when Used

When labeling civil geometry (alignments for example), whichever annotation group that is utilized is copied from the DNGLIB and saved with the active DGN. This is only the case when the geometry being annotated is stored within the active DGN, no...
7 months ago in Drawing Production / OpenRail Designer / OpenRoads Designer / Workspace 0 Future consideration

Issues with Drainage Prompt to compress database

The prompt for compressing the drainage database needs some work: It really should be removed. Salvaging anything marked for deletion but not compressed isn't really feasible in OpenRoads environment. Do not prompt me twice. It should be assumed t...
7 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 1 Future consideration

ORD SUDA - Single gradient property - False for stormwater and wastewater conduit

Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit. "Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
7 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 2 Future consideration

Profile from Top Mesh

We have the ability to create multiple profiles from multiple surfaces at the same time, but there are occasions where I only need to define a single profile line based on multiple surfaces. It would be handy if there was an option to create a pro...
about 1 year ago in Geometry 8 Already exists

For steel beams- When we create stiffeners and use them in cross frame definition, regardless of the method used, the stiffener tables when opened default to the first stiffener in the OBM library rather than the stiffener used in cross frame definition

Currently when we create a new stiffener and then when we create cross frames using those stiffeners, they don't show up when you open stiffener definition after creating cross frames (the first stiffener definition within the selection is shown)
7 months ago in OpenBridge Modeler 0 Needs review

Add Conduit To Existing Profile Run

It would be very helpful if there was a way to simply Add a Conduit to an existing Profile Run. For example, I have a storm network modeled and a bunch of drawings created by using a Profile Run, but now I needed to add another conduit at the end ...
7 months ago in Drainage and Utilities / Drawing Production / OpenRail Designer / OpenRoads Designer 0 Future consideration

Export pier or abutment templates to Functional Component

Often times a small edit is needed to make an existing abutment or pier template match project standards. It is tedious to create a Functional Component from scratch for small edits. It would be helpful to have a tool or button to export a templat...
7 months ago in Modeling 0 Future consideration

Create Top and Bottom Meshes for Surface Templates

Currently ORD will create a top mesh and bottom mesh when a template is assigned to a corridor. However, when a template is assigned to a design non-corridor terrain, no top or bottom meshes are created. Doing so would be very useful for viewing o...
over 2 years ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

shear studs on cross-frames

I'd like to be able to add shear studs on Cross-Frames (specifically Built-up End Diaphragms).
almost 2 years ago in OpenBridge Modeler 0 Future consideration

Analyze point

It would be extremely useful to have Analyze Point on every tab by default. That tool gets utilized a lot to evaluate all kinds of civil geometry.
about 1 year ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 2 Future consideration