Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Bentley Civil Product Ideas

Showing 1740 of 1740

Sorting and Grouping of Corridors and Linear Templates

Currently Corridors and Linear Templates are very poorly sorted in Explorer. These need to at least be sorted alphabetically to allow users to easily find the Corridor/Linear template they are looking for. Our major projects have dozens and dozens...
about 3 years ago in Modeling 0 Future consideration

Don't process corridor for change of disabled Point Control or Parametric Constraint

Not sure why it does this, but it doesnt make sense that the software processes when these are changed although they are disabled. To aid in productivity, especially for large corridors, the corridor should check if the Point Control / Parametric ...
about 3 years ago in Modeling / OpenRail Designer / OpenRoads Designer 2 Future consideration

Allow for different shaft fixity in one model

A column on drilled shafts can have different fixity locations for different load cases. Suggest allowing analysis of the same bridge with different fixities rather then needing to create multiple models with varying fixities for simplicity.
7 months ago in Analytics / OpenBridge Designer 0 Future consideration

Cross Section named boundary by 2 points - Offset Overrides

When we create cross sections for culverts, the cross section often needs to be created at a skew from the centerline. We are able to create these using the 2 Points option. This option, however, is limited. We would like for our cross sections to...
over 2 years ago in Drawing Production / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Search and replace functionality across all cross section models

When needing to change a label or text across all cross sections, it would be very helpful to be able to add a toggle to search and replace text across all models, or select models.
over 2 years ago in Drawing Production / OpenRail Designer / OpenRoads Designer / OpenSite Designer 2 Future consideration

Add option to specify two radii for the Standard Sign Panel: Equilateral Triangle

The Standard Sign Panel: Equilateral Triangle does not have an option to specify separate radius values for the inside and outside of the panel which is needed for creating signs.
7 months ago in OpenRoads SignCAD 0 Future consideration

Please add support for DWG files on import or Attach function

I am using OpenRoads ConceptStation 2024, Tried to load the basic 2D dwg file as reference for a road design work, but system not allowed, current turnaround is convert dwg to dgn which is not best bet. Pease add support for DWG files on "import" ...
about 1 year ago in Import/Export / OpenRoads ConceptStation 0 Future consideration

Allow assignment of VBA Macros by Feature Definition instead of by Alpha Code

In InRoads, multiple alpha codes assigned to a single Feature all shared the same custom codes and other survey settings. Having to duplicate any VBA Feature Macros to every alternative Alpha Codes complicates maintenance and is a source of uninte...
over 2 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Survey 0 Future consideration

Add Import/Export Ability to Terrain Filters

When setting up terrain filters, there is a substantial amount of effort required in multiple dialog boxes. I had created a report for InRoads that created the XML codes needed for its Terrain Import tool's preferences using an XIN file as its sou...
over 2 years ago in Import/Export / OpenRail Designer / OpenRoads Designer / OpenSite Designer / Terrain 0 Future consideration

Add tool to import .prj settings and convert to .dty

This would save time and take out any guesswork for those needing to build custom coordinate systems using settings from a .prj.
about 1 year ago in Import/Export / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration