It would be good to have the option to drag the start and end stations of the profile by variable slope from element in the profile window. Similarly as the partial offset tool in plan. At the moment the user needs to update values in the properti...
Retain item type on 3D cells exported from Points Feature Definition
If there is an item type attached to a Point Feature Definition, it is not retained when the Point is exported as a standard 3D MicroStation cell. The metadata is only retained to the 2d element, not the 3d. In the case of a mesh (from a component...
When exiting out of file. There are Check In, Updated Server Copy, Free, and Close options. Sometimes we want to cancel. This will speed up our workflow because we don't have to wait to get back into the same file.
Have Dynamic Settings built into Create Template window instead of opening from tools menu.
It would be nice to have the dynamic settings options built into the create template window instead of having to open them from the tools menu every time you open the window to create/edit templates. There is plenty of empty space below the templa...
Allow user to define width of superelevation section graphic.
Currently, the graphic representing the superelevation section is hard coded to use the radius of the smallest curve in the alignment. If the radius of the smallest curve is 50 meters or more, the section width is hard-coded to 50 meters.
If t...
Warning Message at Reprocess Corridor when user hasn't updated Superelevation file
Following an amendment to the vertical al
ignment, the corridor file failed to use the associated superE in the re-processed corridor. No error message was shown but the desi
gn no longer followed the design intent.
The root cause of the issue a...
https://www.civildesigner.com/auxiliary-lane-analysis-with-speed-profiling/ Speed Profiling When considering the location of climbing lanes the civil engineer will combine an analysis of the size and length of the grade change with the speed profi...
Automatically calculate values when inputting into property fields
When inputting numbers into property fields, ORD can automatically calculate them for you. Example: Survey field team shoots the top of casting elevation of a manhole at 500ft, then shoots again for a bottom invert of the manhole but only leaves a...
Allow Precision Setting When Labeling Surveys with Numeric Attribute Values
All Attributes are currently treated as text. Some attributes are recorded as numeric data and are being assigned a decimal precision. When these are read to generate labels, there is no option to round those values to a different precision. For e...
Would be nice if Bentley could provide a Superelevation XML file for TAC Canadian users. The AASHTO XML seems to work but it is not compatible with the TAC Canadian standard.