Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Applications

Showing 1304

Openroads Drainage - HGL versus Headwater Analysis for Headwalls Inletting into a Storm Sewer System

Many times, a stream needs to be drained into a storm sewer system via a headwall. When this occurs, two analysis should be considered: The headwater at the headwall (the mechanics of the water getting into the pipe at the headwall). Generally KYT...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

ORD Drainage - Show actual Tc versus Tc Minimum

Many times a calculated Time of Concentration is less than the minimum used for Intensity. When this occurs in a system of drainage areas (catchments), it helps a designer AND a reviewer to see what the actual Time of Concentration is at a given p...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Fix the rotation issue when importing drainage nodes from inroads.

We recently used ORD to import 200 plus drainage structures from inroads to ORD. It brought in the nodes, but the rotation was off. We had to manually rotate the node to the correct angle. Also, the 2-D and 3-D rotation did not match until the nod...
over 1 year ago in OpenRoads Designer 0

Ability to use end condition exceptions on linear templates

Being able to use end condition exceptions for linear templates would be extremely beneficial for roadway designers. We often use end condition exceptions to turn off slopes in order to connect external features like ditches to the corridor. Not b...
almost 2 years ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 2 Future consideration

SUDA - Spread Slope

Make it easier to manage longitudinal spread slope. It's nice to input the slope in the properties per node, but consider making it integrated to the gutters used during bypass flow drawing of gutters.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

Local edits to a template, now out of sync with library.

It would be nice to see what local changes were made, to a template, before Sync'ing to library. It currently notifies user that there changes made, but doesn't show what those changes are. It is difficult to know what changes may have been made t...
4 months ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 0 Future consideration

Static Item Type Expression values

Currently Item Types with Expressions update whenever properties are displayed. etc and are always "live" even via referencing, etc. This causes many issues where the original Excel lookup spreadsheet or Civil data is not present (when viewed in M...
about 2 years ago in Item Types / OpenBridge Designer / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Ablity to connect two nodes directly by flange

For the water supply project, in a situation where we have cast iron elements connected to the flange such as gate valves, hydrants, elbows, venturiers and plastic line pipes. There is no way to connect the two nodes directly through the flange. a...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Components of say a wingwall/abutment/pier written to their specific level

Levels would be able to turned off rather than the whole wingwall
about 2 years ago in OpenBridge Designer / OpenBridge Modeler 0 Future consideration

Export to DWG: Improve and SIMPLIFY

Nowadays, it`s very, very and I can`t stress this enough, difficult to generate a dwg deliverable package for clients. Our market (Brasil) is dominated by AutoDesk, so dwg is a standard. We work on infrastrucure and have some really complex plan l...
over 1 year ago in All Other / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration