Stepped Footing

Add option for Steeped footing in Leap Concrete - Substructure Module
over 1 year ago in OpenBridge Designer 1 Needs review

Modify default Height/Depth of a Node

In current version we do not have flexibility to change height/depth of a node from default 5.25 feet. At times we need lesser deep Nodes which does not require more than 1 or 2 feet of cover from soffit of conduit.
over 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 4 Already exists

Ability to control the cl profile (in a template/corridor) by vector offset method from adjacent corridors on either side.

I would like to control the elevation of my centerline point (point in template) to be controlled by a "vector offset method" by selecting to points (corridor feature) in two corridors that running parallel.
10 months ago in Modeling / OpenRoads Designer 5 Already exists

Create multiple long sections/profiles in the same model space

When creating profiles/long sections for track vertical geometry, ORD creates an individual sheet view and model view for each sheet. This creates a large amount of work when trying to bulk annotate or export long sections for drafting. It would b...
over 1 year ago in Drainage and Utilities / Drawing Production / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Additional Shoulder Rollover Slope Rows (3D Modeling - Templates)

I would like to make a suggestion on an improvement to template design for 3D Modeling in ORD. The Rollover values tool in superelevation template design is incredibly helpful, as it saves time by calculating the proper shoulder super rates accord...
over 1 year ago in OpenRail Designer / OpenRoads Designer / Superelevation 0 Future consideration

Incorrect arc radius for turnout outer curve switch.

For turnout annotation, we need to add turnout with LLS Extension from the library. I know that it is possible to add LLS radius value for a defined curved turnout in the library, but for a complex project where there are a lot of curved turnouts ...
10 months ago in OpenRail Designer / Turnouts/Crossings 0

No subtraction of sleepers from ballast in corridor report

Corridor report does not subtract the volume of sleepers we added to the model from the ballast. I propose to add in the next version of ORD the possibility to subtract in the ballast the added sleepers.
10 months ago in OpenRail Designer / Reports 0 Future consideration

No possibility to set the lower limit height of the profile

When creating profiles using ,,Named Boundary”, I cannot set the lower height limit of the profile. I propose to add in the next part of ORD setting the lower height limit if we want to make one drawing sheet from profile. This would help with the...
10 months ago in Drawing Production / OpenRail Designer 1 Already exists

Frame action or double curvature to be considered when superstructure is integral with substructure

When a superstructure is integral to substructure for Leap Concrete, both girders in the superstructure module and columns in the substructure module analysis/ design should incorporate frame action for any design load cases such as breaking force...
10 months ago in OpenBridge Designer 0 Future consideration

Option to Edit the Loads Font on Leap Conc -> Sub -> Geo Tab

I would like the option to edit the font on the Leap Concrete, Substructure tab, Geometry Tab. This way the text displayed that shows the loads can be increased which can help when saving images for review and record keeping. Thanks
over 1 year ago in OpenBridge Designer 0 Future consideration