Create a rule to set drainage node to (active terrain) when setting elevation reference
Presently when setting reference elevation for the node it lets you set it to the active terrain but does not rule it to the (active terrain). If this were done the inlet tops would automatically adjust as the design terrain changes.
The name of the nodes are defined at placement by the selected Feature Definition. It's common for it to be changed during the design process. For these cases, all altered nodes must be manually renamed. This usually is done through selection or u...
DU: add drop calculation to node invert depending on lowest conduit wall thickness
Some times, most common with concrete conduits, the node invert needs to have a drop in reference to the lowest pipe to acomodate its wall. This would later be filled to match.For construction and BIM purpose, this difference is important. Special...
The current connection region of drainage nodes are available for the side faces of node only. The software should allow the connection region of pipe/conduit from the bottom of the node.
Civil Expression Support for Links / Nodes - NOT BCI-I-361
The mark and intention of was missed for BCI-I-361 with the shipped version. The functionality we are requesting is in the behavior or expansion of the CivilExpression symbol library for reporting purposes on links and nodes.. The described method...
Separate 3D line and 3D object for pipes to different levels.
In Drainage & Utilities, the 3D line and the 3D object for a pipes(conduit/link) is placed on same level. It would be great to have them on different levels - also because it can be a demand from from clients in Denmark, that the line is place...
Enhancement to Group/Join Multiple Nodes in a Structure Node to Match Existing Survey Data
There is currently not a way to join/group multiple nodes to a structure node to match existing survey data. This node join/group capability is needed to match XYZ surveyed invert points (from field collection) and be able to use the Extract from ...
Circular Eccentric Nodes should have the ability to have a rotation point at the center of the structure.
Circular eccentric nodes, like manholes, should have the ability to have a rotation point at the center of the structure and elevation reference at the center of the frame and cover.
Allow Design Scenarios to change proposed conduit properties and class based on depth of conduit.
The class of a pipe is primarily selected by the depth of cover over a pipe. Sometimes vehicle loads or construction loads have an influence on the class selection
If a drainage profile uses a cached view rather than a dynamic one, ORD will provide a notification in the bottom right-hand corner that simply says "Cached References are currently displayed. One or more cached references does not match the curre...