Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Drainage and Utilities

Showing 130

Create a rule to set drainage node to (active terrain) when setting elevation reference

Presently when setting reference elevation for the node it lets you set it to the active terrain but does not rule it to the (active terrain). If this were done the inlet tops would automatically adjust as the design terrain changes.
over 2 years ago in Drainage and Utilities 1 Already exists

DU tool to update node name by feature definition

The name of the nodes are defined at placement by the selected Feature Definition. It's common for it to be changed during the design process. For these cases, all altered nodes must be manually renamed. This usually is done through selection or u...

DU: add drop calculation to node invert depending on lowest conduit wall thickness

Some times, most common with concrete conduits, the node invert needs to have a drop in reference to the lowest pipe to acomodate its wall. This would later be filled to match.For construction and BIM purpose, this difference is important. Special...
over 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 3 Already exists

Connection Region in Bottom of Node

The current connection region of drainage nodes are available for the side faces of node only. The software should allow the connection region of pipe/conduit from the bottom of the node.
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Civil Expression Support for Links / Nodes - NOT BCI-I-361

The mark and intention of was missed for BCI-I-361 with the shipped version. The functionality we are requesting is in the behavior or expansion of the CivilExpression symbol library for reporting purposes on links and nodes.. The described method...
2 months ago in Drainage and Utilities / Item Types / OpenRail Designer / OpenRoads Designer 0 Future consideration

Separate 3D line and 3D object for pipes to different levels.

In Drainage & Utilities, the 3D line and the 3D object for a pipes(conduit/link) is placed on same level. It would be great to have them on different levels - also because it can be a demand from from clients in Denmark, that the line is place...
about 1 year ago in Drainage and Utilities 3 Already exists

Enhancement to Group/Join Multiple Nodes in a Structure Node to Match Existing Survey Data

There is currently not a way to join/group multiple nodes to a structure node to match existing survey data. This node join/group capability is needed to match XYZ surveyed invert points (from field collection) and be able to use the Extract from ...
over 1 year ago in Drainage and Utilities 0 Future consideration

Circular Eccentric Nodes should have the ability to have a rotation point at the center of the structure.

Circular eccentric nodes, like manholes, should have the ability to have a rotation point at the center of the structure and elevation reference at the center of the frame and cover.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Allow Design Scenarios to change proposed conduit properties and class based on depth of conduit.

The class of a pipe is primarily selected by the depth of cover over a pipe. Sometimes vehicle loads or construction loads have an influence on the class selection
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Provide a list of Outdated Cached References

If a drainage profile uses a cached view rather than a dynamic one, ORD will provide a notification in the bottom right-hand corner that simply says "Cached References are currently displayed. One or more cached references does not match the curre...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration