ORD Drainage - Separate CUlverts and Storm Sewer Pipes into Completely Separate Design Windows
Having to click 'Is Culvert' is just one more placve an error can take place in design. Creating spearate design windows for each of these elements will minimize this potential, and will make it easier for reviews as well.
contour labeling that is somewhat view dependent, this goes for Label Terrain Contour tool as well
contour labels that are upside down our difficult to read. It would be advantageous to have all labels orientated correctly on each sheet (regardless of the north direction).
Create Template Geometry - Option to create 2D Elements from points located below top surface
Currently only template points located on top surface can produce 2d linear elements. This also only seems possible, when the components they belong to, are not ‘Excluded From Top/Bottom Mesh’ (option in Component properties dialog) and the ‘Creat...
The existing Annotation settings offer a plan readability setting to invert text if it would otherwise appear upside down. This appears to be tied to design file orientation. For this to really be useful, it needs to function according to the fina...
Currently, is possible to create and personalice reports (Analise)using Item Types data, however,there is no relation back. It would be very benifecial if data added or even changed into the reports could be imported back into the model and Item T...
For the modeling and model review process, it would be helpful to have Description fields for common corridor inputs, such as Parametric Constraints, Point Controls, etc. that can be easily discovered using the Corridor Objects tool.
The ability to show the cross-pipes in profile runs right now is by default a user preference. It would be nice if this could just be a standard function or at least set to "True" as a default to be turned off if desired.
Add Offset Format options to the Baseline Offset Text Favorite
Add the Offset Format options that are available for the Point Offset text favorite (Positive Prefix, Negative Prefix, Positive Suffix, Negative Suffix, and Show Sign) to the Drainage Baseline Offset text favorite.
I have imported several groups of horizontal event points such as viaduct start and endpoints. The points include their point description. I would like to report Station, Easting, Northing and the point description but the "Horizontal Alignment Ev...
Graphical display of corridor parametric constraints
It would be more efficient to be able to see the station limits of parametric constraints graphically on screen with a control line in plan view and be able to change these stations and values dynamically similar to point controls. The only option...