Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 1751 of 1751

Do not upgrade reference files with Civil File Manager

When upgrading files with Civil File Manager, the tool also tries to upgrades reference files. We need the ability for the tool not to try updating the references.
3 months ago in All Other / OpenRail Designer / OpenRoads Designer 1 Future consideration

Drainage module conduits and nodes data to be added to Cross section Frame

Road Cross section are able to display template, Design and existing terrain surface within the frame. But if theres drainage infrastructure there is no way of displaying that data within the frame it has to be done as a point annotation.
22 days ago in Drainage and Utilities / OpenRoads Designer 0 Needs review

Enhancement to Introduce the Remapping Capability on Terrain Model’s Source Path

There is currently not a way to remap the terrain model’s source path in ORD. This capability is needed to be able to push survey data updates via rewriting a .tin file to then update from source (sourcing back to the rewritten .tin file with surv...
about 2 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Terrain 0 Future consideration

Creating a Surface Area Report

A physical report containing all surface areas and total area. Application use cases for this would include: -Useful for project planning and cost estimation. -Help determine material quantities. -Assists in environmental impact assessments by pro...
12 months ago in OpenRoads Designer / Reports 1 Future consideration

Tool to Convert a Survey Linear to a Civil Geometry Complex Element or a MicroStation Linestring

There should be a one button command to convert a Survey Linear to a Civil Geometry Complex Element, a MicroStation Linestring, or individual MicroStation lines (User picks what they want). There are ways to accomplish this process now but most in...
over 2 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Survey 5 Future consideration

Superelevation Frame Annotation can annotate the 0% cross slope location

As part of the profile superelevation annotation, the annotation currently cannot annotate the location where the superelevation is 0%. This would be helpful to show in plans and for designers to easily see the station this point is at.
over 2 years ago in Annotation / OpenRail Designer / OpenRoads Designer 1 Future consideration

Add a Geometry Connector tool for Vertical Geometry

Cuurently OpenRail implements a tool called Geometry Connector (similar to Multiple Horizontal element Regression Analysis in Power Rail Track). However similar geometry tool is not available for vertical geometry calculations. It would be possibl...
over 2 years ago in Geometry 1 Future consideration

Add option to HorizontalAlignmentCheckIntegrity.xsl report to ignore angular differences for PIs with no curves.

In the InRoads Check Integrity command, the command would report "OK" for any PIs that did not have curves. We would like the ORD check integrity reports to not report issues at a PI if there are no curves present.
over 2 years ago in OpenRoads Designer / Reports 0 Future consideration

Template Display Rules for Null Points

Template Display Rules are very powerful and widely used in corridor modeling workflows. However, Display Rules are only available for components. We would like to extend this functionality to the Null Points. This would open new possibilities for...
almost 3 years ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Seperating the "add point control/parametric constraint" and "delete point control/parametric constraint" buttons within the corridor objects tool.

Many times a day I accidently delete a point control or parametric constraint when I'm trying to add. The buttons are extremely close, is there a way to move the delete button further away?
11 months ago in OpenRail Designer / OpenRoads Designer / User Interface 0 Future consideration