Make Survey Attribution Easier to Import

Currently, ORD cannot process more than two attributes from a survey data file into their own unique attribute column. The workaround is tedious and unintuitive: First, modify the CSV file from the data collector (not good practice to modify a sur...
about 1 year ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Survey 0 Needs review

Revise Limitation to LEAP/RC-Pier Wind Load Auto Generation Tool

I have brought the limitation to the Wind Load Auto Generation tool in the past, but this is becoming more important and an issue now, since I’ve been getting many comments from our clients and my coworkers on this. Currently, the wind load auto g...
over 1 year ago in OpenBridge Designer 0 Future consideration

Target Alias Sort by Name

Suggesting to sort the Target Alias list by name and increase the width so long concatenated names can be fully read.
about 2 years ago in Modeling / OpenRail Designer / OpenRoads Designer / User Interface 0 Future consideration

Annotation Group Definition Copied to Active File when Used

When labeling civil geometry (alignments for example), whichever annotation group that is utilized is copied from the DNGLIB and saved with the active DGN. This is only the case when the geometry being annotated is stored within the active DGN, no...
7 months ago in Drawing Production / OpenRail Designer / OpenRoads Designer / Workspace 0 Future consideration

Issues with Drainage Prompt to compress database

The prompt for compressing the drainage database needs some work: It really should be removed. Salvaging anything marked for deletion but not compressed isn't really feasible in OpenRoads environment. Do not prompt me twice. It should be assumed t...
7 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 1 Future consideration

ORD SUDA - Single gradient property - False for stormwater and wastewater conduit

Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit. "Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
7 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 2 Future consideration

Add WorkSet-wide project components to Explorer

It would be extremely useful to be able to have a list of all the project components in a WorkSet easily accessible from the explorer, regardless of what dgn you are in. Exactly like the sheet index tool but for terrain models, alignments, corrido...
almost 3 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface / Workspace 0 Future consideration

Quick Horizontal Regression by Slew

The ability to have a tool or a checkbox that lets you run a quick horizontal regression for the alignment that is entirely controlled by the slew value input and not a 'tolerance' value. This would make the quick horizontal regression tool much m...
about 2 years ago in OpenRail Designer / Regression Analysis 0 Future consideration

Stationing Text "View Readable" Setting to Honor Rotated Views

The "View Readable" Setting (SEE IMAGE 1) Should: Display text as readable when looking left up the page when the alignment is at zero degrees as the industry standard ( SEE IMAGE 2)(note that the view is unrotated and North is pointing up) Honor ...

For steel beams- When we create stiffeners and use them in cross frame definition, regardless of the method used, the stiffener tables when opened default to the first stiffener in the OBM library rather than the stiffener used in cross frame definition

Currently when we create a new stiffener and then when we create cross frames using those stiffeners, they don't show up when you open stiffener definition after creating cross frames (the first stiffener definition within the selection is shown)