Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Functional Areas

Showing 1346

Place a sanitary pipe that follows a terrain at a specific depth of cover.

It appears that the software currently doesn’t allow sanitary conduit FDs to follow a slope even when the FD is set to depth of cover. it would be nice to tell the program to follow a given depth under the terrain, so I can see the pipe slope vary...
about 1 year ago in Drainage and Utilities 9 Already exists

Target Alias Sort by Name

Suggesting to sort the Target Alias list by name and increase the width so long concatenated names can be fully read.
almost 2 years ago in Modeling / OpenRail Designer / OpenRoads Designer / User Interface 0 Future consideration

Move IP to change vertical alignments

Editing the location of an intersection point by just clicking and moving it was possible in PowerRail track - can we have that functionality back as it's a good tool to quickly see changes in alignment when optioneering.
over 2 years ago in Geometry / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Already exists

Add an end element in xml file

To make it easier to select and report the end of an alignment it would be good to have an "Alignment End point" or "Alignment end element" in plan and profile. Also in cant!
8 months ago in Reports 0 Needs review

Control Precision of Terrain High and Low Points

Control precision of High and Low point annotation in Element Templates instead of reading "Accuracy" in Design File Settings. Set precision in the Element Template>Calculated Feature Settings>High/Low Points settings.
over 2 years ago in Annotation / OpenRail Designer / OpenRoads Designer / OpenSite Designer / Terrain 0 Future consideration

Dimension style for Major Contours Indexing Text

Need ability to set Major contours indexing text according to dimension style. Currently it is set for TextStyle.
over 1 year ago in Annotation / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Hide underground and above ground pipes and equipment

Using OpenSite Designer, is there a way to hide items, i.e. pipe, valves, and equipment, below a surface? These components are on multiple elevations above and below this surface. All components are on the same level, i.e., WATER. Client does not ...
over 1 year ago in Modeling / OpenSite Designer 2 Needs review

ORD D&U - Import / Export WaterCAD models

Ability to import /export to network data from/to OpenFlows WaterCAD in order to collaborate with BIM workflows.
over 1 year ago in Drainage and Utilities 0 Needs review

Allow for components volumes to be added to unclassified cut or fill volume

This would allow for users to include the backfill volume and obtain one set of cut/fill volumes. The current process requires the user to manually add the backfill volume. One example of this is in the case of a retaining wall and the fill that...
over 2 years ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Visualization of Flood Fill based on min and max height values

A function of flood fill a portion of the terrain based on a min height and max height value. It allows a drainage engineer to visually check if a certain flood top water level will flow beyond the project boundary. Is there a way to do this in Op...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration