Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Ideas

Showing 1716 of 1716

ORD SUDA - Single gradient property - False for stormwater and wastewater conduit

Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit. "Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
8 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 2 Future consideration

Turnout points for tounge position

In railway engineering, there is a growing demand for positioning of the tongue in turnouts. The proposal is to introduce a new point in the Feature Definition of turnouts, making it possible to specify the distance from point .1 to the Tongue. Su...
over 1 year ago in OpenRail Designer / Turnouts/Crossings 0 Future consideration

Ignore Specific Survey Observations

InRoads had the ability to ignore specific survey observations. If ORD had that same capability that would be fantastic.
over 2 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Survey 0 Future consideration

Add the overall Spiral PI station and Northing and Easting to all the Horizonal Alignment reports in CivilGeometry..

When comping existing alignments, we have a need to match the overall Spiral PI data. Adding this to the Report would make the workflow easier.
almost 2 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Reports 0 Future consideration

For steel beams- When we create stiffeners and use them in cross frame definition, regardless of the method used, the stiffener tables when opened default to the first stiffener in the OBM library rather than the stiffener used in cross frame definition

Currently when we create a new stiffener and then when we create cross frames using those stiffeners, they don't show up when you open stiffener definition after creating cross frames (the first stiffener definition within the selection is shown)
8 months ago in OpenBridge Modeler 0 Needs review

Add Conduit To Existing Profile Run

It would be very helpful if there was a way to simply Add a Conduit to an existing Profile Run. For example, I have a storm network modeled and a bunch of drawings created by using a Profile Run, but now I needed to add another conduit at the end ...
8 months ago in Drainage and Utilities / Drawing Production / OpenRail Designer / OpenRoads Designer 0 Future consideration

Export pier or abutment templates to Functional Component

Often times a small edit is needed to make an existing abutment or pier template match project standards. It is tedious to create a Functional Component from scratch for small edits. It would be helpful to have a tool or button to export a templat...
8 months ago in Modeling 0 Future consideration

Best Match Field Code Option

In ORD 10.11 and beyond the Best Match Field Code Option is now a drop-down of the following: Match exact: Feature Must equal an Alpha Code, only exact matches. For example if there is a Feature Definition with Alpha Code set to AP (Asphalt Paveme...
over 1 year ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Survey 0 Future consideration

Filter Features by Name

The graphical filter is limited to feature element symbology and feature definition. Multiple, redundant, feature definitions must be created in order to import features to multiple surfaces. The feature names, assigned in the template, can be use...
about 3 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Terrain 0 Future consideration

Folders for Cant Tables

In order to use Cant Tables, a significant number of Cant Tables need to be created. As such, the ability to organize the tables into folders within the DGNLIB is needed.
about 3 years ago in CANT / OpenRail Designer 0 Future consideration