ORD SUDA - Single gradient property - False for stormwater and wastewater conduit
Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit.
"Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
Provide a tool to quickly create infield gradings. When creating infield gradings, often we only to include part of a geometry element instead of the entire element. Because the terrain from element tool doesn't have the option to only import part...
Report Station Equations in Horizontal Alignment report similar to GeoPAK
Horizontal geometry reports are confusing when there are station equations at cardinal points. A few of our surveyors have commented on this and I can see where they’re coming from.
I’ve attached three example geometry reports. Their names ind...
Show Projected 3D Cuts when using the Project Run Tool
If we project the profile runs to centerline, we lose the ability to show the utility crossings generated by the 3D cut at the pipe centerline. We can add a 3D cut at the road centerline, but often the crossing utilities are not in the same locati...
For steel beams- When we create stiffeners and use them in cross frame definition, regardless of the method used, the stiffener tables when opened default to the first stiffener in the OBM library rather than the stiffener used in cross frame definition
Currently when we create a new stiffener and then when we create cross frames using those stiffeners, they don't show up when you open stiffener definition after creating cross frames (the first stiffener definition within the selection is shown)
It would be very helpful if there was a way to simply Add a Conduit to an existing Profile Run. For example, I have a storm network modeled and a bunch of drawings created by using a Profile Run, but now I needed to add another conduit at the end ...
When using display rules Type it would be useful to have an option of values between A-B, not only >, = , and >=. This way you can choose between multiple versions of a component. Example absolute horizontal 0-1 Curb type F, 1-2 type A, 2-3 ...
Ability to modify 'Rational Method Frequency Adjustment Factor' for a specific catchment or range of catchments.
Currently there is only an option to add Rational Method Frequency Adjustment Factors for the entire storm, which affects all catchments. Our GDOT standards require modification of the factor for only C values less than 0.6.
Based on the way the new regression tools work for importing regression lines we no longer have a way of running gauge and cant reports on existing alignments based on LHR/RHR surveys.