Wasn't sure whether to post this to technical support as a bug or here. This is a tiny concern in the greater scheme of things but a frustration nonetheless. Suppose you use civil analysis tool to track a horizontal alignment with an active vertic...
Warn users while detaching references whose labels are annotated in active file
civil labeler allows us to label civil geometry elements from reference files. Simply placing labels appears to apply the civil schema to the active dgn file.User like to have a warning when users detach reference files whose elements are labeled ...
It would be great if ORD had the capability to connect a channel directly to an On Grade Inlet to be able to calculate spread and bypass at the inlet. Currently the workaround is to connect the channel to a Generic Outfall at the edge of the inlet...
Profile projection tools for crossfall relative to Target element
In legacy software, we had the option to either project crossfall from one element to another relative/normal to the reference element or relative/normal to the target element. We do not seem to have this functionality in ORD currently (although t...
It's very hard and troublesome to create elevation countours for cut and fill or layer thickness. The legends values have to be updated by hand for each new terrain. And in the end, it`s actually just a Display Style applied to the terrain or the ...
leap bridge steel -- Add Str III combination to default combinations
The user insists of adding Str III as a default combinations. It may be useful to create a default Str III combination (since now we have WL considered under design) instead of forcing the user to create a new combination that accepts WL. Please s...
Surface Template - "Process Corridor" similar tool
Just add the function to process the template again so it can be updated. This is a major issue when using surface templates with clipping boundaries. If I change the clipping boundary (a simple shape on the 2D model), I have to delete and reapply...
Update the Minnesota M1-6M, M1-6a and M1-X4 county shields for 3-digits
MnDOT wants to start using wider 3-digit sizes (22.5"x18", 30"x24" & 45"x36") for some of the county shields within the Minnesota standard in OpenRoads SignCAD. The wider 3-digit sizes are needed for the M1-6M and M1-6a blue pentagon county sh...
Compare real data from a tunnel with its theoretical corridor
Hello. We're building a tunnel and need OpenTunnel to be able to compare the actual data from the constructed tunnel (recorded via scanning) with the theoretical data from the designed tunnel corridor. There are other programs that do this: Istram...