Add Offset Format options to the Baseline Offset Text Favorite
Add the Offset Format options that are available for the Point Offset text favorite (Positive Prefix, Negative Prefix, Positive Suffix, Negative Suffix, and Show Sign) to the Drainage Baseline Offset text favorite.
Add ability to set default Engineering Libraries for all users
As it stands, I can make a new Engineering Library on a network drive to share with other users, but if I wanted to make that library the "default", I can't without having to make the change for each individual user.
Maintain Item Types when extracting drainage or utility model from survey graphics.
When using "Extract From Graphic" tool to create a drainage or utility model object, the extraction process fails to bring the Item Type from the source object (in this example a surveyed gas line), leading the user to reattach the Item Type to th...
Ability to Export Profile Run To Consider Node Length
Currently it is not possible to export the alignment and profile from Profile Run with same station as it considers the nodes in the profile. We can select the conduit and export it, but this would be actual conduit length not the center to center...
Many times a calculated Time of Concentration is less than the minimum used for Intensity. When this occurs in a system of drainage areas (catchments), it helps a designer AND a reviewer to see what the actual Time of Concentration is at a given p...
Circular Eccentric MH Feature Definitions Rotation Reference Point Addition
The insertion point for circular eccentric manhole feature definitions is at the center of the MH 2D top. When it's rotated, it rotates at that point instead of the center of the 3D base. Please create the ability to use the insertion point to set...
The prompt for compressing the drainage database needs some work: It really should be removed. Salvaging anything marked for deletion but not compressed isn't really feasible in OpenRoads environment. Do not prompt me twice. It should be assumed t...
ORD SUDA - Single gradient property - False for stormwater and wastewater conduit
Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit.
"Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
Need ability to define variable wall thickness on conduits
For box shaped conduits, we need to be able to define top, bottom and side wall thicknesses independently. This allows modeling of box shapes which correspond to physical construction.
It would be very helpful if there was a way to simply Add a Conduit to an existing Profile Run. For example, I have a storm network modeled and a bunch of drawings created by using a Profile Run, but now I needed to add another conduit at the end ...