Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Drainage and Utilities

Showing 70

ORD SUDA - Single gradient property - False for stormwater and wastewater conduit

Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit. "Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
4 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 2 Future consideration

Add Conduit To Existing Profile Run

It would be very helpful if there was a way to simply Add a Conduit to an existing Profile Run. For example, I have a storm network modeled and a bunch of drawings created by using a Profile Run, but now I needed to add another conduit at the end ...
4 months ago in Drainage and Utilities / Drawing Production / OpenRail Designer / OpenRoads Designer 0 Future consideration

ORD Drainage - Show actual Tc versus Tc Minimum

Many times a calculated Time of Concentration is less than the minimum used for Intensity. When this occurs in a system of drainage areas (catchments), it helps a designer AND a reviewer to see what the actual Time of Concentration is at a given p...
about 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Civil Expression Support for Links / Nodes - NOT BCI-I-361

The mark and intention of was missed for BCI-I-361 with the shipped version. The functionality we are requesting is in the behavior or expansion of the CivilExpression symbol library for reporting purposes on links and nodes.. The described method...
4 months ago in Drainage and Utilities / Item Types / OpenRail Designer / OpenRoads Designer 0 Future consideration

Need ability to define variable wall thickness on conduits

For box shaped conduits, we need to be able to define top, bottom and side wall thicknesses independently. This allows modeling of box shapes which correspond to physical construction.
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Ablity to connect two nodes directly by flange

For the water supply project, in a situation where we have cast iron elements connected to the flange such as gate valves, hydrants, elbows, venturiers and plastic line pipes. There is no way to connect the two nodes directly through the flange. a...
over 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Utility Enhancements

Add the conduit table options similar to drainage for managing conduit sizes, materials, etc... Right now you have to input a conduit table for each utility type and can't import a table from utility to utility. Just need one set of tables to mana...
over 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer / Workspace 0 Future consideration

Openroads Drainage - HGL versus Headwater Analysis for Headwalls Inletting into a Storm Sewer System

Many times, a stream needs to be drained into a storm sewer system via a headwall. When this occurs, two analysis should be considered: The headwater at the headwall (the mechanics of the water getting into the pipe at the headwall). Generally KYT...
about 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Add profile annotation location option for annotating conduit description only once

If a conduit is perfectly straight, then it is easy to put the description once in the middle, but if the conduit has any bends then each segment gets annotated. Adding an option for annotation frequency with location controls would fix this.
over 2 years ago in Annotation / Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Needs ability to set RIM Depression Depth

Needs ability to add RIM Depression Depth with elevation (ground). Currently we can only set the Elevation (RIm) but not any depression value.
over 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration