Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Drainage and Utilities

Showing 120 of 1556

Custom Grate Spacing and Sizes

It would be amazing if we could utilize our own grate spacing for calculating the head on inlets. KYTC has several grates that don't quite match with what is in the delivered system, and this may affect the depth of the head on the inlet.
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

Element Templates Point to Multiple Cells

At KYTC we like to show the vaults of drainage structures, in order to do that S&S drew them for us. ORD does that in 3D, however, we turn the 3D off when producing plans. It would help in the case that we could point to two cells (one that ma...
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

Profile Annotation Groups

A lot of our project show multiple profiles in one profile view (EG, Proposed PGL, RT Gutter, LT Gutter, etc.). In MicroStation we set up a specific .ddb file that would plot the text labels in the desired location. We haven’t been successful in c...

Generate Report of Construction Pipe Lengths, Start-Stop Station, and Offsets based on Keymap

Would like to utilized Asset Manager or a similar tool to quickly obtain quantities for drainage structures, namely pipes, based on a keymap. The idea is to feed the tool a keymap file, a file containing shapes representing each sheet, the tool us...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Gutter spread - flip side

Why do gutters not have a "side" as spread when drawn appear in the right side.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

If no Design Lenghts in Catalog - Ignore or Set Design Inlet Openings to false

I do not see a place to force in a Inlet Catalog to set "Design Inlet Opening" to false, so I would like the software to assume False if lenghts are NOT in the catalog.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Needs review

DU: conduit wall thickness improvement

Follow up for my other idea BCI-I-494 (link https://bentleyopencivil.ideas.aha.io/ideas/BCI-I-494). The feature was implemented, but it still missing some core functions. What it does now, is add the drop on a design scenario. If the setting is tu...

Clip Conduits (pipes) at inside edge of Drainage Structures and Report "True" Horizontal Lengths and Vertical Lengths in the Properties

This is more than useful; this is absolutely required. When laying out Drainage Networks, pipes need to be trimmed at the inside edge of the structures, and the "True" pipe lengths (horizontal & vertical) need to be provided in the properties....
8 months ago in Drainage and Utilities / Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 5 Already exists

Add By Linear Element option to Analyze Catchment (by Terrain Model) tool

Be able to select a linear element (eg. edge of road pavement) that the Analyze Catchment tool computes catchment areas from a terrain model for. The tool currently only has a Use Fence option which can still take a long time. If one can narrow it...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

ORD SUDA profiling network (Conduits)

When Profiling (SUDA) networks. There's an option to quickly change nodes to show either line, box, slice etc. Need same option for Conduits. There's one agency we deal with daily that they only want to see single (stick) lines when profiling a se...
over 1 year ago in Drainage and Utilities 2 Needs review